<?xml version="1.0" encoding="UTF-8"?><rss version="2.0" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Off-Grid GX Guide: Victron Venus OS and GX Monitoring</title><description>Independent, unofficial guides to Victron Venus OS and GX energy monitoring, built from published official documentation.</description><link>https://offgridgxguide.com/</link><language>en</language><atom:link href="https://offgridgxguide.com/rss.xml" rel="self" type="application/rss+xml"/><item><title>Read Battery SoC in Node-RED on Venus OS Large</title><link>https://offgridgxguide.com/posts/venus-os-large-node-red-battery-monitoring/</link><guid isPermaLink="true">https://offgridgxguide.com/posts/venus-os-large-node-red-battery-monitoring/</guid><description>Switch a Cerbo GX or Ekrano GX to Venus OS Large, open the local Node-RED editor, and read battery state of charge in a two-node Debug flow.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;On a Cerbo GX or Ekrano GX that already shows battery state of charge (SoC), install Venus OS Large and enable Node-RED. In the editor, set the Victron &lt;strong&gt;System (input)&lt;/strong&gt; node to &lt;strong&gt;Battery State of Charge (%)&lt;/strong&gt; and connect it to &lt;strong&gt;Debug&lt;/strong&gt; to read the percentage. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt; &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/wiki/Input-nodes&quot;&gt;Victron input nodes&lt;/a&gt; &lt;a href=&quot;https://nodered.org/docs/tutorials/first-flow&quot;&gt;Node-RED first flow&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Confirm the GX already shows battery SoC&lt;/h2&gt;
&lt;p&gt;Open &lt;strong&gt;Overview&lt;/strong&gt; and check that it shows a battery percentage. Check &lt;strong&gt;Settings → System Setup → Batteries → Battery monitor&lt;/strong&gt; for the SoC source setting. The selected source determines the SoC shown on &lt;strong&gt;Overview&lt;/strong&gt;. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/configuration.html&quot;&gt;Ekrano GX configuration&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Install Venus OS Large&lt;/h2&gt;
&lt;p&gt;Use the GX menus for the firmware update. On a Cerbo GX without a display, use &lt;strong&gt;Remote Console&lt;/strong&gt; to reach the same menus. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/firmware-updates.html&quot;&gt;Cerbo GX firmware updates&lt;/a&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Update the current firmware first. Go to &lt;strong&gt;Settings → General → Firmware → Online updates&lt;/strong&gt; and choose &lt;strong&gt;Check for updates&lt;/strong&gt;. If a new version appears under &lt;strong&gt;Update available&lt;/strong&gt;, press to install it. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/firmware-updates.html&quot;&gt;Cerbo GX firmware updates&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/firmware-updates.html&quot;&gt;Ekrano GX firmware updates&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;In &lt;strong&gt;Online updates&lt;/strong&gt;, open &lt;strong&gt;Image type&lt;/strong&gt; and select &lt;strong&gt;Large&lt;/strong&gt;. Go back one level, choose &lt;strong&gt;Check for updates&lt;/strong&gt;, and install the version shown under &lt;strong&gt;Update available&lt;/strong&gt;. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/firmware-updates.html&quot;&gt;Cerbo GX firmware updates&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/firmware-updates.html&quot;&gt;Ekrano GX firmware updates&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Wait for the GX to download the firmware and reboot for installation. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Enable Node-RED on the GX&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;After the reboot, go to &lt;strong&gt;Settings → General → Access &amp;amp; Security&lt;/strong&gt; and set &lt;strong&gt;Access level&lt;/strong&gt; to &lt;strong&gt;User &amp;amp; Installer&lt;/strong&gt; if needed. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/configuration.html&quot;&gt;Ekrano GX configuration&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Go to &lt;strong&gt;Settings → Integrations → Venus OS Large Features&lt;/strong&gt; and enable &lt;strong&gt;Node-RED&lt;/strong&gt;. The presence of the Large features menu confirms the image is installed. Changing this setting requires installer access. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/configuration.html&quot;&gt;Ekrano GX configuration&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Open the local Node-RED editor&lt;/h2&gt;
&lt;p&gt;From a browser on the local network, open &lt;code&gt;https://venus.local:1881/&lt;/code&gt;. If you need to substitute an IP address for the name, use &lt;code&gt;https://&amp;lt;GX-IP&amp;gt;:1881/&lt;/code&gt; with the GX&apos;s local IP address. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;On the GX, find &lt;strong&gt;IP address&lt;/strong&gt; under &lt;strong&gt;Settings → Connectivity → Ethernet&lt;/strong&gt; or &lt;strong&gt;Settings → Connectivity → Wi-Fi&lt;/strong&gt;, depending on which connection the GX uses. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/configuration.html&quot;&gt;Ekrano GX configuration&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The editor uses a self-signed certificate, so the browser can show a privacy warning. &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/blob/master/docs/INSTALL.md&quot;&gt;Victron nodes installation guide&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the warning appears when you open your GX&apos;s local editor address, choose &lt;strong&gt;Advanced&lt;/strong&gt; or &lt;strong&gt;Show Details&lt;/strong&gt;, depending on the browser, then choose the option to visit the site. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the editor asks you to sign in on Venus OS v3.50 or later with the &lt;strong&gt;Weak&lt;/strong&gt; or &lt;strong&gt;Secured&lt;/strong&gt; profile set, use &lt;code&gt;admin&lt;/code&gt; and the password configured for that profile. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Build and deploy the SoC flow&lt;/h2&gt;
&lt;p&gt;Venus OS Large includes the Victron nodes in the Node-RED palette. &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/blob/master/docs/INSTALL.md&quot;&gt;Victron nodes installation guide&lt;/a&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Add &lt;strong&gt;System (input)&lt;/strong&gt; to the workspace. Set &lt;strong&gt;Measurement&lt;/strong&gt; to &lt;strong&gt;Battery State of Charge (%)&lt;/strong&gt;, which reads &lt;code&gt;/Dc/Battery/Soc&lt;/code&gt;. Click &lt;strong&gt;Done&lt;/strong&gt; to save the node settings. &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/wiki/Input-nodes&quot;&gt;Victron input nodes&lt;/a&gt; &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/blob/master/src/nodes/victron-nodes.html&quot;&gt;Victron editor source&lt;/a&gt; &lt;a href=&quot;https://nodered.org/docs/tutorials/first-flow&quot;&gt;Node-RED first flow&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Add a &lt;strong&gt;Debug&lt;/strong&gt; node and keep its default payload display. Drag from the System node&apos;s output port to the Debug node&apos;s input port. &lt;a href=&quot;https://nodered.org/docs/tutorials/first-flow&quot;&gt;Node-RED first flow&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Click &lt;strong&gt;Deploy&lt;/strong&gt; and open the &lt;strong&gt;Debug&lt;/strong&gt; sidebar. &lt;a href=&quot;https://nodered.org/docs/tutorials/first-flow&quot;&gt;Node-RED first flow&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;The Victron input puts the measurement in &lt;code&gt;msg.payload&lt;/code&gt;, and Debug displays that payload by default. &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/blob/master/src/nodes/victron-nodes.js&quot;&gt;Victron runtime source&lt;/a&gt; &lt;a href=&quot;https://nodered.org/docs/tutorials/first-flow&quot;&gt;Node-RED first flow&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The payload for this measurement is a percentage. &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/wiki/Input-nodes&quot;&gt;Victron input nodes&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;If Debug stays blank&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Check that &lt;strong&gt;Battery State of Charge (%)&lt;/strong&gt; is selected, the two nodes are connected, and you clicked &lt;strong&gt;Deploy&lt;/strong&gt;. &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/wiki/Input-nodes&quot;&gt;Victron input nodes&lt;/a&gt; &lt;a href=&quot;https://nodered.org/docs/tutorials/first-flow&quot;&gt;Node-RED first flow&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Make sure the Debug node is enabled, set the sidebar filter to &lt;strong&gt;all nodes&lt;/strong&gt;, and resume the sidebar if it is paused. A paused sidebar drops incoming messages. &lt;a href=&quot;https://nodered.org/docs/user-guide/editor/sidebar/debug&quot;&gt;Node-RED Debug sidebar&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Check whether &lt;strong&gt;Only changes&lt;/strong&gt; is selected on the Victron node. Clear it and click &lt;strong&gt;Deploy&lt;/strong&gt; again to allow the node to send the current value even while SoC stays steady. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:large&quot;&gt;Victron Large image guide&lt;/a&gt; &lt;a href=&quot;https://github.com/victronenergy/node-red-contrib-victron/blob/master/src/nodes/victron-nodes.html&quot;&gt;Victron editor source&lt;/a&gt; &lt;a href=&quot;https://nodered.org/docs/tutorials/first-flow&quot;&gt;Node-RED first flow&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Evidence and limits&lt;/h2&gt;
&lt;p&gt;The setup follows Victron&apos;s GX manuals and Large image guide, with the sign-in steps covering Venus OS v3.50 and later. The read-only flow follows the Victron input-node reference and the Node-RED editor documentation. The documentation was checked on 2026-11-27. No hands-on testing was performed for this guide.&lt;/p&gt;
</content:encoded><category>victron</category><category>venus-os</category><category>node-red</category><category>battery-monitoring</category><author>Off-Grid GX Guide Editorial</author></item><item><title>Set Up Victron VRM Remote Monitoring on Cerbo GX</title><link>https://offgridgxguide.com/posts/victron-vrm-remote-monitoring-cerbo-gx/</link><guid isPermaLink="true">https://offgridgxguide.com/posts/victron-vrm-remote-monitoring-cerbo-gx/</guid><description>Set up Victron VRM on an online Cerbo GX. Find the Portal ID, verify live updates and logged readings, and set up an email alert for missing data.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;On an internet-connected Cerbo GX, set the &lt;strong&gt;VRM Portal&lt;/strong&gt; mode to &lt;strong&gt;Read-only&lt;/strong&gt; for remote monitoring. Once VRM receives the first transmission, add the GX to your account using its &lt;strong&gt;VRM Portal ID&lt;/strong&gt;. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/getting-started-with-vrm.html&quot;&gt;VRM setup and registration&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Choose the VRM access mode&lt;/h2&gt;
&lt;p&gt;On the GX, open &lt;strong&gt;Settings → VRM → VRM Portal&lt;/strong&gt;. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Mode&lt;/th&gt;
&lt;th&gt;What it allows&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Off&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Turns off the VRM connection. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Read-only&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Allows monitoring and blocks remote settings changes and firmware updates. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Full&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Enables full remote access and management. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;The VRM Portal manual lists the same setting under &lt;strong&gt;Settings → VRM Online Portal → VRM Portal&lt;/strong&gt; on the GX. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/getting-started-with-vrm.html&quot;&gt;VRM setup requirements&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Confirm the first upload&lt;/h2&gt;
&lt;p&gt;On the Cerbo GX, open &lt;strong&gt;Settings → VRM → Last contact&lt;/strong&gt; and compare the time shown with the configured &lt;strong&gt;Log interval&lt;/strong&gt;. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/vrm-portal.html&quot;&gt;Cerbo GX logging checks&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;What &lt;strong&gt;Last contact&lt;/strong&gt; shows&lt;/th&gt;
&lt;th&gt;What it means&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;A contact within the configured &lt;strong&gt;Log interval&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;The GX is sending data successfully. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/vrm-portal.html&quot;&gt;Cerbo GX logging checks&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Dashes&lt;/td&gt;
&lt;td&gt;No VRM contact since power-up. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/vrm-portal.html&quot;&gt;Cerbo GX logging checks&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;A previous contact and a current error&lt;/td&gt;
&lt;td&gt;The GX sent data previously and has since lost its connection. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/vrm-portal.html&quot;&gt;Cerbo GX logging checks&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;In the same menu, check &lt;strong&gt;Connection status&lt;/strong&gt; for a communication error and &lt;strong&gt;Stored records&lt;/strong&gt; for the number of data records stored locally while the device was offline. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Add the Cerbo GX to your VRM account&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Copy the &lt;strong&gt;VRM Portal ID&lt;/strong&gt; from &lt;strong&gt;Settings → VRM&lt;/strong&gt; on the Cerbo GX, or read it from the label on the side of the unit. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Cerbo GX configuration&lt;/a&gt; &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/getting-started-with-vrm.html&quot;&gt;VRM setup requirements&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Go to &lt;code&gt;vrm.victronenergy.com&lt;/code&gt; and choose &lt;strong&gt;Login&lt;/strong&gt;. To create an account, choose &lt;strong&gt;Register for free&lt;/strong&gt;, complete the form, click &lt;strong&gt;Register&lt;/strong&gt;, and activate the account using the confirmation email. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/getting-started-with-vrm.html&quot;&gt;VRM account setup&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Choose &lt;strong&gt;Add installation&lt;/strong&gt; in the left menu. Select the option for a GX device, enter the &lt;strong&gt;VRM Portal ID&lt;/strong&gt;, and click &lt;strong&gt;Request access&lt;/strong&gt;. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/getting-started-with-vrm.html&quot;&gt;VRM registration&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;The first account to register the installation gets Admin access. Later accounts that try to add the same &lt;strong&gt;VRM Portal ID&lt;/strong&gt; need the site owner’s approval. VRM emails the owner when another account requests access using that ID. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/getting-started-with-vrm.html&quot;&gt;VRM registration&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Verify live readings and logged data&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;&lt;strong&gt;Live readings.&lt;/strong&gt; Open the installation in VRM and turn on &lt;strong&gt;Settings → General → Realtime updates&lt;/strong&gt;. On the Dashboard, check &lt;strong&gt;Last updated&lt;/strong&gt; at the top of the page for real-time mode. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/real-time-data.html&quot;&gt;VRM real-time data&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Logged data.&lt;/strong&gt; Check the Dashboard’s historical data block for a graph. The graph depends on the information available. If the block shows a line graph, its readings depend on the products installed. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/dashboard.html&quot;&gt;VRM Portal Dashboard&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check a specific time window.&lt;/strong&gt; Open &lt;strong&gt;Advanced&lt;/strong&gt; in the VRM sidebar and choose a time range with the date picker. If needed, use the widget button at the upper right to enable a chart for an installed device, then look for readings in that range. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/advanced-dashboard---analyse-the-data-of-an-installation.html&quot;&gt;VRM Advanced Dashboard&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;Real-time updates require Venus OS v2.60 or later, a good internet connection, sufficient GX CPU resources, and &lt;strong&gt;Read-only&lt;/strong&gt; or &lt;strong&gt;Full&lt;/strong&gt; on the GX. VRM’s stored readings follow the configured logging interval. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/real-time-data.html&quot;&gt;VRM real-time data&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The installation’s &lt;strong&gt;Settings&lt;/strong&gt; menu is visible to accounts with Admin or Technician access. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/getting-started-with-vrm.html&quot;&gt;VRM installation settings&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Enable the no-data alert and check email delivery&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;In the VRM installation, open &lt;strong&gt;Settings → Alarm rules&lt;/strong&gt; and turn on &lt;strong&gt;Communication monitoring&lt;/strong&gt;. Use &lt;strong&gt;Notify after&lt;/strong&gt; to extend how long VRM waits beyond the GX &lt;strong&gt;Log interval&lt;/strong&gt; without receiving data before sending a no-data alarm. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/alarms-and-monitoring.html&quot;&gt;VRM communication monitoring&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;In the left menu, choose &lt;strong&gt;BACK&lt;/strong&gt;, then open &lt;strong&gt;Preferences → Notifications&lt;/strong&gt;. Under &lt;strong&gt;Notification settings for this device&lt;/strong&gt;, turn on &lt;strong&gt;E-mail&lt;/strong&gt;. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/alarms-and-monitoring.html&quot;&gt;VRM email notifications&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Select &lt;strong&gt;Send a test notification&lt;/strong&gt; and confirm that the test message arrives by email. &lt;a href=&quot;https://www.victronenergy.com/media/pg/VRM_Portal_manual/en/alarms-and-monitoring.html&quot;&gt;VRM email notifications&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Evidence and scope&lt;/h2&gt;
&lt;p&gt;Victron’s online Cerbo GX and VRM Portal manuals were checked on 2026-11-27. The steps cover monitoring setup on a Cerbo GX that already has internet access. For hardware installation, follow the manufacturer’s manual and local rules. No hands-on testing was performed for this guide.&lt;/p&gt;
</content:encoded><category>cerbo-gx</category><category>victron-vrm</category><category>remote-monitoring</category><category>alerts</category><author>Off-Grid GX Guide Editorial</author></item><item><title>Cerbo GX vs Cerbo-S GX vs Ekrano GX: Buying Guide</title><link>https://offgridgxguide.com/posts/cerbo-gx-cerbo-s-gx-ekrano-gx-hardware/</link><guid isPermaLink="true">https://offgridgxguide.com/posts/cerbo-gx-cerbo-s-gx-ekrano-gx-hardware/</guid><description>Compare Victron GX controllers by CAN ports, sensor inputs and display options. Check Cerbo revisions and find the right fit before you buy.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Choose the Cerbo-S GX if one CAN network is enough and you have no tank or temperature sensors to wire directly. Choose the Cerbo GX MK2 or MK3 for more sensor inputs and two configurable CAN networks. Choose the Ekrano GX if you want a built-in 7-inch touchscreen. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:start&quot;&gt;Victron GX comparison&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/technical-specifications.html&quot;&gt;Cerbo GX specifications&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/connecting-victron-products.html&quot;&gt;Cerbo-S GX connections&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Check the Cerbo model number&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Original Cerbo GX (BPP900450100)&lt;/strong&gt; has a non-isolated VE.Can interface and a dedicated 500 kbit/s BMS-Can interface. It can suit a system that needs those two networks and uses a compatible battery. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:start&quot;&gt;Victron GX comparison, notes 15 and 26&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Cerbo GX MK2 (BPP900450110 or BPP900451100)&lt;/strong&gt; and &lt;strong&gt;MK3 (BPP900451130)&lt;/strong&gt; have VE.Can 1 and VE.Can 2. Both are configurable. VE.Can 1 is isolated and VE.Can 2 is non-isolated. Ask for the part number if the listing only says “Cerbo GX.” &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/technical-specifications.html&quot;&gt;Cerbo GX specifications&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html&quot;&gt;Cerbo GX CAN interfaces&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Hardware at a glance&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Published specification&lt;/th&gt;
&lt;th&gt;Cerbo-S GX&lt;/th&gt;
&lt;th&gt;Original Cerbo GX&lt;/th&gt;
&lt;th&gt;Cerbo GX MK2 / MK3&lt;/th&gt;
&lt;th&gt;Ekrano GX&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Local display&lt;/td&gt;
&lt;td&gt;Optional GX Touch&lt;/td&gt;
&lt;td&gt;Optional GX Touch&lt;/td&gt;
&lt;td&gt;Optional GX Touch&lt;/td&gt;
&lt;td&gt;Built-in 7-inch touchscreen&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Independent CAN interfaces&lt;/td&gt;
&lt;td&gt;1 configurable, non-isolated&lt;/td&gt;
&lt;td&gt;1 VE.Can + 1 fixed BMS-Can&lt;/td&gt;
&lt;td&gt;2 configurable&lt;/td&gt;
&lt;td&gt;2 configurable, one isolated&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VE.Bus&lt;/td&gt;
&lt;td&gt;1 bus, 2 parallel RJ45 sockets&lt;/td&gt;
&lt;td&gt;1 bus, 2 parallel RJ45 sockets&lt;/td&gt;
&lt;td&gt;1 bus, 2 parallel RJ45 sockets&lt;/td&gt;
&lt;td&gt;1 bus, 2 parallel RJ45 sockets&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Physical VE.Direct ports&lt;/td&gt;
&lt;td&gt;3&lt;/td&gt;
&lt;td&gt;3&lt;/td&gt;
&lt;td&gt;3&lt;/td&gt;
&lt;td&gt;3&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Published VE.Direct device maximum, including USB adapters&lt;/td&gt;
&lt;td&gt;15 (may be lower in complex systems)&lt;/td&gt;
&lt;td&gt;15 (limit depends mainly on available CPU processing power)&lt;/td&gt;
&lt;td&gt;15 on MK2, 25 on MK3 (limits depend mainly on available CPU processing power)&lt;/td&gt;
&lt;td&gt;25 (may be lower in complex systems)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;USB host ports&lt;/td&gt;
&lt;td&gt;2, plus 1 power-only USB port&lt;/td&gt;
&lt;td&gt;2, plus 1 power-only USB port for the GX Touch&lt;/td&gt;
&lt;td&gt;3&lt;/td&gt;
&lt;td&gt;2&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Resistive tank inputs&lt;/td&gt;
&lt;td&gt;0&lt;/td&gt;
&lt;td&gt;4&lt;/td&gt;
&lt;td&gt;4&lt;/td&gt;
&lt;td&gt;3&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Temperature inputs&lt;/td&gt;
&lt;td&gt;0&lt;/td&gt;
&lt;td&gt;4&lt;/td&gt;
&lt;td&gt;4&lt;/td&gt;
&lt;td&gt;2&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Digital inputs&lt;/td&gt;
&lt;td&gt;4&lt;/td&gt;
&lt;td&gt;4&lt;/td&gt;
&lt;td&gt;4&lt;/td&gt;
&lt;td&gt;2&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Relays&lt;/td&gt;
&lt;td&gt;2&lt;/td&gt;
&lt;td&gt;2&lt;/td&gt;
&lt;td&gt;2&lt;/td&gt;
&lt;td&gt;2&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;DC supply range&lt;/td&gt;
&lt;td&gt;8–70 V&lt;/td&gt;
&lt;td&gt;8–70 V&lt;/td&gt;
&lt;td&gt;8–70 V&lt;/td&gt;
&lt;td&gt;8–70 V&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Controller mounting&lt;/td&gt;
&lt;td&gt;Wall or DIN rail (requires DIN35 adapter small)&lt;/td&gt;
&lt;td&gt;Wall or DIN rail (requires DIN35 Adapter)&lt;/td&gt;
&lt;td&gt;Wall or DIN rail (requires DIN35 Adapter)&lt;/td&gt;
&lt;td&gt;Panel cut-out with rear steel bracket or front-mount springs&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Enclosure (H × W × D)&lt;/td&gt;
&lt;td&gt;78 × 154 × 48 mm&lt;/td&gt;
&lt;td&gt;78 × 154 × 48 mm&lt;/td&gt;
&lt;td&gt;78 × 154 × 48 mm&lt;/td&gt;
&lt;td&gt;124 × 187 × 29.8 mm, excluding connectors and mounting hardware&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;a href=&quot;https://www.victronenergy.com/live/venus-os:start&quot;&gt;Original Cerbo GX comparison&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/technical-specifications.html&quot;&gt;Cerbo-S GX specifications&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/installation.html&quot;&gt;Cerbo-S GX ports&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/technical-specifications.html&quot;&gt;Cerbo GX MK2/MK3 specifications&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/installation.html&quot;&gt;Cerbo GX MK2/MK3 ports&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/technical-specifications.html&quot;&gt;Ekrano GX specifications&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/installation.html&quot;&gt;Ekrano GX connections&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Work out how many CAN networks you need&lt;/h2&gt;
&lt;p&gt;The Cerbo-S GX has two RJ45 sockets on one VE.Can interface. For a managed lithium battery on Victron’s compatibility list, use BMS-Can at 500 kbit/s if required, or select &lt;strong&gt;VE.Can &amp;amp; CAN-bus BMS (250 kbit/s)&lt;/strong&gt; if specified for that battery. Check the exact battery model before choosing a profile. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/connecting-victron-products.html&quot;&gt;Cerbo-S GX CAN profiles&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/live/battery_compatibility:start&quot;&gt;Victron battery compatibility&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Suppose your supported battery requires BMS-Can at 500 kbit/s and your solar charger requires VE.Can at 250 kbit/s. Assign the battery and charger one CAN interface each. On an original Cerbo GX, use the dedicated BMS-Can interface for the battery and VE.Can for the charger. On an MK2, MK3 or Ekrano GX, set one interface to each profile. A Cerbo-S GX can serve only one of these networks at a time. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:start&quot;&gt;Original Cerbo GX CAN ports&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/connecting-victron-products.html&quot;&gt;Cerbo-S GX CAN interfaces&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html&quot;&gt;Cerbo GX CAN profiles&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/connecting-victron-products.html&quot;&gt;Ekrano GX CAN profiles&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Check sensors, screen and mounting before ordering&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Count the wired senders.&lt;/strong&gt; If you need four compatible resistive tank senders wired directly to the GX controller, choose a Cerbo GX. If you prefer the Cerbo-S GX and have compatible current or voltage senders, the USB-connected GX Tank 140 is an option. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:start&quot;&gt;Victron GX comparison&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/technical-specifications.html&quot;&gt;Cerbo GX specifications&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/technical-specifications.html&quot;&gt;Ekrano GX specifications&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/connecting-victron-products.html&quot;&gt;GX Tank 140 compatibility&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Plan the GX Touch cable route.&lt;/strong&gt; If you want a local touchscreen on either Cerbo, choose the 5-inch GX Touch 50 or 7-inch GX Touch 70. Check that the 2 m cable reaches the controller and leaves room for its HDMI and USB plugs. For browser access to the Cerbo-S GX on the local network, use Remote Console. &lt;a href=&quot;https://www.victronenergy.com/live/venus-os:start&quot;&gt;GX Touch compatibility&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/technical-specifications.html&quot;&gt;GX Touch specifications&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/installation.html&quot;&gt;GX Touch mounting and cable&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo-S_GX/en/accessing-the-gx-device.html&quot;&gt;Victron Remote Console access&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check rear access for the Ekrano GX.&lt;/strong&gt; Use Victron’s cut-out template to check panel fit. The front is rated IP54 with the rear steel bracket and IP31 with the front-mount springs. Use that difference when choosing a mounting position. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/installation.html&quot;&gt;Ekrano GX mounting instructions&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Ekrano_GX/en/technical-specifications.html&quot;&gt;Ekrano GX protection ratings&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;em&gt;Evidence and limits.&lt;/em&gt; Specifications are drawn from Victron’s HTML manuals for the Cerbo GX MK2 and MK3, Cerbo-S GX and Ekrano GX, plus the October 2025 Victron GX comparison for the original Cerbo GX. The example was not run on hardware.&lt;/p&gt;
&lt;p&gt;&lt;a href=&quot;/posts/&quot;&gt;Browse all guides&lt;/a&gt;&lt;/p&gt;
</content:encoded><category>victron</category><category>cerbo-gx</category><category>ekrano-gx</category><category>gx-hardware</category><author>Off-Grid GX Guide Editorial</author></item><item><title>Victron Cerbo GX vs Raspberry Pi Running Venus OS</title><link>https://offgridgxguide.com/posts/victron-cerbo-gx-raspberry-pi-running-venus-os/</link><guid isPermaLink="true">https://offgridgxguide.com/posts/victron-cerbo-gx-raspberry-pi-running-venus-os/</guid><description>Compare Cerbo GX and Raspberry Pi 4 ports, match Victron gear to the right adapters, and calculate the full hardware cost before you buy.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Choose a Cerbo GX MK2 or MK3 if you want built-in VE.Direct, VE.Bus and VE.Can ports. A Raspberry Pi 4 running Venus OS is worth pricing if you already own the board, power supply and SD card. Compare the full parts lists, including the interfaces that connect the Pi to your Victron gear. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/technical-specifications.html&quot;&gt;Cerbo GX specifications&lt;/a&gt;, &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/raspberrypi-install-venus-image&quot;&gt;Venus OS on Raspberry Pi&lt;/a&gt;.&lt;/p&gt;
&lt;h2&gt;Ports and adapters&lt;/h2&gt;
&lt;p&gt;Start with the communication port on each device you plan to connect. The table covers the Cerbo GX MK2 and MK3 and the Raspberry Pi 4 using the &lt;code&gt;raspberrypi4&lt;/code&gt; Venus OS image. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/technical-specifications.html&quot;&gt;Cerbo GX specifications&lt;/a&gt;, &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/installation.html&quot;&gt;Cerbo GX installation&lt;/a&gt;, &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/raspberrypi-install-venus-image&quot;&gt;Venus OS on Raspberry Pi&lt;/a&gt;.&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Connection&lt;/th&gt;
&lt;th&gt;Cerbo GX MK2 and MK3&lt;/th&gt;
&lt;th&gt;Raspberry Pi 4&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;VE.Direct&lt;/td&gt;
&lt;td&gt;3 isolated ports&lt;/td&gt;
&lt;td&gt;Use a Victron VE.Direct to USB interface for products that support GX communication over VE.Direct. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html&quot;&gt;Cerbo GX connection guide&lt;/a&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VE.Bus&lt;/td&gt;
&lt;td&gt;2 parallel RJ45 sockets on one isolated VE.Bus interface&lt;/td&gt;
&lt;td&gt;Add a Victron MK3-USB interface for a VE.Bus inverter/charger.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VE.Can&lt;/td&gt;
&lt;td&gt;2 configurable interfaces. VE.Can 1 is isolated and VE.Can 2 is non-isolated.&lt;/td&gt;
&lt;td&gt;Price a Peak PCAN-USB for VE.Can. See the &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/RaspberryPi-CAN-Interfaces&quot;&gt;Venus OS CAN compatibility guide&lt;/a&gt; for setup.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Sensors and relays&lt;/td&gt;
&lt;td&gt;4 resistive tank inputs, 4 temperature inputs, 4 digital inputs and 2 relays&lt;/td&gt;
&lt;td&gt;GPIO header.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Ethernet and USB&lt;/td&gt;
&lt;td&gt;10/100 Ethernet and 3 USB host ports&lt;/td&gt;
&lt;td&gt;Ethernet and USB&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Display connectors&lt;/td&gt;
&lt;td&gt;HDMI. GX Touch is a separate accessory.&lt;/td&gt;
&lt;td&gt;HDMI output&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;A Pi handling both VE.Can and BMS-Can needs a separate CAN channel for each bus. The Cerbo GX MK2 and MK3 have two independently configurable CAN interfaces. On the Pi, the Venus OS wiki warns that multiple CAN interfaces can change numbering after a reboot unless a udev rule assigns fixed names. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html&quot;&gt;Cerbo GX connection guide&lt;/a&gt;, &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/RaspberryPi-CAN-Interfaces&quot;&gt;Venus OS CAN compatibility guide&lt;/a&gt;.&lt;/p&gt;
&lt;h2&gt;Compare the total hardware cost&lt;/h2&gt;
&lt;p&gt;Use the same equipment list for both quotes. This example connects one VE.Direct MPPT solar charger and one VE.Bus Multi inverter/charger and uses Remote Console without a local display. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html&quot;&gt;Cerbo GX connection guide&lt;/a&gt;, &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/technical-specifications.html&quot;&gt;Cerbo GX specifications&lt;/a&gt;, &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/raspberrypi-install-venus-image&quot;&gt;Venus OS on Raspberry Pi&lt;/a&gt;.&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Basket&lt;/th&gt;
&lt;th&gt;What to price&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Cerbo GX&lt;/td&gt;
&lt;td&gt;Cerbo GX MK2 or MK3, one VE.Direct cable and one RJ45 UTP cable. The fused DC power lead comes with the Cerbo. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/introduction.html&quot;&gt;Box contents&lt;/a&gt;, &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html&quot;&gt;connection guide&lt;/a&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Raspberry Pi&lt;/td&gt;
&lt;td&gt;Pi 4 board, SD card, power supply, one VE.Direct to USB interface and one MK3-USB with a straight-through network cable. &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/raspberrypi-install-venus-image&quot;&gt;Venus OS on Raspberry Pi&lt;/a&gt;, &lt;a href=&quot;https://www.victronenergy.com/media/pg/VEConfigure_Manual/en/troubleshooting.html&quot;&gt;MK3-USB connection&lt;/a&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;For a VE.Can setup, add the bus cable and any terminators you need to buy. The Cerbo includes two VE.Can terminators. The Pi basket also needs the CAN interface. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/introduction.html&quot;&gt;Cerbo GX box contents&lt;/a&gt;, &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html&quot;&gt;Cerbo GX connection guide&lt;/a&gt;, &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/RaspberryPi-CAN-Interfaces&quot;&gt;Venus OS CAN compatibility guide&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;Raspberry Pi announced &lt;strong&gt;$67.50 for the 2 GB Pi 4&lt;/strong&gt; on October 1, 2026. Victron&apos;s recommended list uses euros before VAT. Compare local quotes in one currency with the same treatment of tax and shipping. &lt;a href=&quot;https://www.raspberrypi.com/news/price-increases-for-2gb-raspberry-pi-4-and-raspberry-pi-5/&quot;&gt;Raspberry Pi pricing announcement&lt;/a&gt;, &lt;a href=&quot;https://www.victronenergy.com/information/pricelist&quot;&gt;Victron price list&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;For the &lt;strong&gt;break-even calculation&lt;/strong&gt;, subtract the Pi board quote from the complete Cerbo basket. If your board quote is $67.50, subtract $67.50. The Pi costs less if its remaining parts cost less than that difference. If you already have the board, enter zero for it when comparing new spending.&lt;/p&gt;
&lt;h2&gt;Which should you choose?&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Cerbo GX MK2 or MK3&lt;/strong&gt; suits a system that needs two separate CAN buses, built-in tank or temperature inputs, or Victron&apos;s commercial product support. The unit accepts 8 to 70 V DC and includes the fused power lead. Installations above 60 V DC must prevent user access to the terminals. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/installation.html&quot;&gt;Cerbo GX installation&lt;/a&gt;, &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html&quot;&gt;connection guide&lt;/a&gt;, &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/raspberrypi-install-venus-image&quot;&gt;Venus OS support note&lt;/a&gt;.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Raspberry Pi 4&lt;/strong&gt; suits a setup whose adapter list is short and whose completed basket costs less. The wiki lists Venus OS v2.70 or newer for Pi 4 board revisions 1.2 and 1.3, and v2.90 or newer for revisions 1.4 and 1.5. The image is community-supported, with help through Victron Community&apos;s Modifications section. &lt;a href=&quot;https://github.com/victronenergy/venus/wiki/raspberrypi-install-venus-image&quot;&gt;Venus OS on Raspberry Pi&lt;/a&gt;.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; Published specifications and pricing were checked on November 26, 2026, against Victron&apos;s MK2/MK3 web manual, the Venus OS wiki&apos;s Raspberry Pi 4 image documentation and Raspberry Pi&apos;s pricing announcement. Neither configuration was run for this guide.&lt;/p&gt;
</content:encoded><category>victron</category><category>cerbo-gx</category><category>raspberry-pi</category><category>venus-os</category><author>Off-Grid GX Guide Editorial</author></item><item><title>Victron Venus OS to Home Assistant via MQTT or Modbus TCP</title><link>https://offgridgxguide.com/posts/connecting-victron-venus-os-home-assistant-via-mqtt/</link><guid isPermaLink="true">https://offgridgxguide.com/posts/connecting-victron-venus-os-home-assistant-via-mqtt/</guid><description>Connect Victron Venus OS to Home Assistant with the built-in MQTT integration, or use Modbus TCP to poll a specific register. See both setups.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Use Home Assistant’s built-in &lt;strong&gt;Victron GX&lt;/strong&gt; integration over MQTT to discover supported sensors. Use &lt;strong&gt;Modbus TCP&lt;/strong&gt; if you want to poll specific Venus OS registers and define each sensor yourself. Both setups use the GX device on your local network. &lt;a href=&quot;https://www.home-assistant.io/integrations/victron_gx/&quot;&gt;Home Assistant Victron GX&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/modbus&quot;&gt;Home Assistant Modbus&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;&lt;/th&gt;
&lt;th&gt;MQTT with Victron GX&lt;/th&gt;
&lt;th&gt;Modbus TCP&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Setup in Home Assistant&lt;/td&gt;
&lt;td&gt;Add Victron GX from &lt;strong&gt;Devices &amp;amp; services&lt;/strong&gt;.&lt;/td&gt;
&lt;td&gt;Add a TCP hub and a sensor for each reading in &lt;code&gt;configuration.yaml&lt;/code&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;How readings arrive&lt;/td&gt;
&lt;td&gt;GX pushes values via MQTT. Home Assistant may briefly delay fast-changing readings, depending on the metric.&lt;/td&gt;
&lt;td&gt;Home Assistant uses the sensor’s unit ID and register address when polling.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;When to choose it&lt;/td&gt;
&lt;td&gt;You want Home Assistant to create entities for supported equipment, such as a battery monitor or solar charger.&lt;/td&gt;
&lt;td&gt;You want an explicit register mapping and control over the polling interval.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;a href=&quot;https://www.home-assistant.io/integrations/victron_gx/&quot;&gt;Home Assistant Victron GX&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/modbus&quot;&gt;Home Assistant Modbus&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Connect over MQTT&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;In the Cerbo GX console, open &lt;strong&gt;Settings → Integrations → MQTT Access&lt;/strong&gt; and enable &lt;strong&gt;MQTT Access&lt;/strong&gt;. Note the GX IP address under &lt;strong&gt;Settings → Connectivity → Ethernet&lt;/strong&gt; or &lt;strong&gt;Wi-Fi&lt;/strong&gt;, whichever the GX uses. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Victron Cerbo GX configuration&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;In Home Assistant, open &lt;strong&gt;Settings → Devices &amp;amp; services&lt;/strong&gt; and select the discovered &lt;strong&gt;Victron GX&lt;/strong&gt; entry if it appears. Otherwise select &lt;strong&gt;Add Integration&lt;/strong&gt;, choose &lt;strong&gt;Victron GX&lt;/strong&gt;, and enter the GX hostname or IP address when prompted. Home Assistant introduced this integration in version 2026.5. &lt;a href=&quot;https://www.home-assistant.io/integrations/victron_gx/#configuration&quot;&gt;Home Assistant Victron GX setup&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;For a GX using the &lt;strong&gt;Secured&lt;/strong&gt; profile, select port &lt;code&gt;8883&lt;/code&gt; and enable &lt;strong&gt;SSL&lt;/strong&gt; if entering the connection details manually. For the &lt;strong&gt;Unsecured&lt;/strong&gt; profile, use port &lt;code&gt;1883&lt;/code&gt;, disable &lt;strong&gt;SSL&lt;/strong&gt;, and leave the username and password blank. The &lt;strong&gt;Weak&lt;/strong&gt; and &lt;strong&gt;Secured&lt;/strong&gt; profiles require a password configured on the GX. Home Assistant tries TLS first for discovered devices and falls back to unencrypted MQTT on &lt;code&gt;1883&lt;/code&gt; if TLS is unavailable. &lt;a href=&quot;https://www.home-assistant.io/integrations/victron_gx/#configuration&quot;&gt;Home Assistant Victron GX setup&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;If Home Assistant asks you to pair, open &lt;strong&gt;Settings → Integrations → MQTT Devices → Pairing mode&lt;/strong&gt; on the GX. Enable pairing and select &lt;strong&gt;Submit&lt;/strong&gt; in Home Assistant within 120 seconds. For manual setup on a secured GX without token pairing, leave the username blank on a standard installation and enter the local GX password when prompted. &lt;a href=&quot;https://www.home-assistant.io/integrations/victron_gx/#configuration&quot;&gt;Home Assistant Victron GX setup&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;Open the &lt;strong&gt;Victron GX&lt;/strong&gt; integration and select &lt;strong&gt;Entities&lt;/strong&gt;. Look for battery state of charge, solar power, or another reading your equipment provides. If setup succeeds but no entities appear, confirm &lt;strong&gt;MQTT Access&lt;/strong&gt; is enabled and check &lt;strong&gt;Settings → System → Logs&lt;/strong&gt; in Home Assistant. &lt;a href=&quot;https://www.home-assistant.io/integrations/victron_gx/&quot;&gt;Home Assistant Victron GX entities and troubleshooting&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Connect over Modbus TCP&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;On a Cerbo GX, open &lt;strong&gt;Settings → Integrations → Modbus TCP Server&lt;/strong&gt; and turn on &lt;strong&gt;Enable Modbus TCP Server&lt;/strong&gt;. For a read-only setup, select read-only under &lt;strong&gt;Access permissions&lt;/strong&gt;. Victron introduced this option in Venus OS 3.70. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Victron Cerbo GX configuration&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/blog/2026/2/25/introducing-venus-os-3-70/&quot;&gt;Venus OS 3.70 release notes&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Open &lt;strong&gt;Available services&lt;/strong&gt; in the same menu to find the unit ID for a particular device. For whole-system readings, Victron specifies unit ID &lt;code&gt;100&lt;/code&gt; for &lt;code&gt;com.victronenergy.system&lt;/code&gt;. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Victron Cerbo GX configuration&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/live/ccgx%3Amodbustcp_faq&quot;&gt;Victron GX Modbus-TCP Manual&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Add the hub below to Home Assistant’s &lt;code&gt;configuration.yaml&lt;/code&gt;. Replace &lt;code&gt;IP_ADDRESS&lt;/code&gt; with the GX IP address. If you already have a top-level &lt;code&gt;modbus:&lt;/code&gt; list, add the new hub to that list. &lt;a href=&quot;https://www.home-assistant.io/integrations/modbus&quot;&gt;Home Assistant Modbus setup&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/troubleshooting.html&quot;&gt;Cerbo GX network ports&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;Victron maps system battery state of charge to register &lt;code&gt;843&lt;/code&gt; as an unsigned 16-bit percentage with a scale factor of one. This example reads it as a holding register. &lt;a href=&quot;https://raw.githubusercontent.com/victronenergy/dbus_modbustcp/master/attributes.csv#L355&quot;&gt;Victron Modbus register definitions&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/live/ccgx%3Amodbustcp_faq&quot;&gt;Victron GX Modbus-TCP Manual&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-yaml&quot;&gt;modbus:
  - name: victron_gx_modbus
    type: tcp
    host: IP_ADDRESS
    port: 502
    sensors:
      - name: &amp;quot;Victron System Battery Charge&amp;quot;
        device_address: 100
        address: 843
        input_type: holding
        data_type: uint16
        unit_of_measurement: &amp;quot;%&amp;quot;
        scan_interval: 15
&lt;/code&gt;&lt;/pre&gt;
&lt;p&gt;Check the YAML configuration and restart Home Assistant. The example polls the register every 15 seconds. &lt;a href=&quot;https://www.home-assistant.io/docs/configuration/&quot;&gt;Home Assistant configuration guide&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/modbus&quot;&gt;Home Assistant Modbus setup&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;For another register, match its data type and conversion. For example, Victron’s system battery voltage register &lt;code&gt;840&lt;/code&gt; uses a divisor of ten. Use &lt;code&gt;scale: 0.1&lt;/code&gt; and &lt;code&gt;precision: 1&lt;/code&gt; in Home Assistant to convert that reading to volts with one decimal place. &lt;a href=&quot;https://raw.githubusercontent.com/victronenergy/dbus_modbustcp/master/attributes.csv#L352&quot;&gt;Victron Modbus register definitions&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/modbus#configuring-sensor-entities&quot;&gt;Home Assistant Modbus sensor options&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Verify the battery reading&lt;/h2&gt;
&lt;p&gt;As a Home Assistant administrator, go to &lt;strong&gt;Settings → Tools → States&lt;/strong&gt; and filter for the battery state-of-charge entity. For MQTT, use the reading from the battery monitor selected on the GX. For the Modbus example, look for &lt;strong&gt;Victron System Battery Charge&lt;/strong&gt;. Compare the percentage with the Cerbo GX &lt;strong&gt;Overview&lt;/strong&gt; screen once the reading has updated. &lt;a href=&quot;https://www.home-assistant.io/docs/tools/dev-tools/#states-tab&quot;&gt;Home Assistant States tool&lt;/a&gt; · &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Victron Cerbo GX battery state of charge&lt;/a&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;The GX also has no battery percentage.&lt;/strong&gt; On a Cerbo GX, check the selected source under &lt;strong&gt;Settings → System Setup → Batteries → Battery monitor&lt;/strong&gt;. The GX gets state of charge from a connected device. &lt;a href=&quot;https://www.victronenergy.com/media/pg/Cerbo_GX/en/configuration.html&quot;&gt;Victron Cerbo GX battery state of charge&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Modbus connects but the register read fails.&lt;/strong&gt; Check the unit ID and register together. Victron’s &lt;code&gt;0x02&lt;/code&gt; response means the unit ID exists but at least one requested register does not. &lt;a href=&quot;https://www.victronenergy.com/live/ccgx%3Amodbustcp_faq&quot;&gt;Victron GX Modbus-TCP Manual&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;MQTT setup reports an authentication error.&lt;/strong&gt; Verify the GX &lt;strong&gt;Local Network Security Profile&lt;/strong&gt; under &lt;strong&gt;Settings → General&lt;/strong&gt;. Use the password configured on the GX for password-based local setup. &lt;a href=&quot;https://www.home-assistant.io/integrations/victron_gx/#authentication-failed&quot;&gt;Home Assistant Victron GX troubleshooting&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;em&gt;Evidence and limits. Documentation was checked on November 26, 2026. The procedure follows the Cerbo GX manual, the Venus OS 3.70 release notes for Modbus read-only access, and the Home Assistant 2026.11.3 documentation. No hardware test was performed.&lt;/em&gt;&lt;/p&gt;
</content:encoded><category>victron</category><category>venus-os</category><category>home-assistant</category><category>mqtt</category><category>modbus-tcp</category><author>Off-Grid GX Guide Editorial</author></item></channel></rss>